beautypg.com

6 hard disk procedures, Preparation, Procedures – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 605: Commands

background image

Procedures 12-41

Octel Overture 200/300 Serenade 3.0

PB60014–01

12.6

HARD DISK PROCEDURES

This section describes the procedures used for restoring, replacing, adding, and removing a hard disk drive, and for
upgrading languages. This section also describes the hard disk drive utility programs used while performing the hard
disk procedures.

Preparation

The following equipment is needed for the Hard Disk Procedures and should be assembled and verified prior to
starting.

-

Hard disk drive(s) to be used for replacement

-

Software diskettes for the current release

-

System prompt diskettes for the current release

.

Verify that the software diskettes and system prompt diskettes are for the same software release.

-

A terminal and printer (or terminal with hardcopy capability) for communicating with the Octel Overture
200/300 and for obtaining a printed copy of all message server inputs and responses.

Procedures

The Hard Disk Procedures included in this section are

-

ADD. To add a drive to a message server. Refer to Hard Disk Add in this section.

-

REMOVE. To remove a drive from a multiple-drive message server. Refer to Hard Disk Remove in this
section.

-

REPLACE. To replace a disk drive in a multiple-drive message server. Refer to Hard Disk Replace in this
section.

-

RESTORE. To restore a message server to operation when system drive(s) must be replaced or the software is
to be updated. Refer to Hard Disk Restore in this section.

Commands

The utility programs used while performing the hard disk procedures are

-

DSKMAP

-

DSKTST

-

DISKO

DSKMAP

The

DSKMAP

utility displays the last known status of all drives as recorded by the Voice Control Unit (VCU) in the

Octel Overture 200/300.

DSKMAP

can be run from the hard disk or from the software diskette.