1.2

USING INSTALL

The customer’s specific configuration needs should be determined and a configuration package
completed before the installation begins. Use the configuration package to answer each question in
the INSTALL program. A blank configuration package can be found at the end of the Understanding
Configuration chapter in the Configuration volume.

Follow the directions in the Installation and Maintenance volume, Installation chapter, Connecting
Terminals section, to connect your terminal to the Octel Overture

t200/300 message server.

Entering the INSTALL Program

Enter the maintenance-level password to access the message-server database. If this is a new
installation and the password has not been changed, enter the maintenance-level password set by the
manufacturer.

Caution!

You should change the manufacturer password to
ensure the security of the server. Refer to the
Configuration volume, Understanding Configuration
chapter, Assuring Security section.

At the @ prompt, on the terminal, type

INSTA

or

INSTAL

and press

Enter

. The terminal displays

the following messages:

@INSTA

–––––––– SYSTEM INSTALLATION DIALOG ––––––––
DAY MM/DD/YYYY HH:MM:SS SYSTEMNAME ID:XXXXX S/N:XXXXXX PBX:00

INSTALL then identifies the type of installation.

-

New installation.
INSTALL question 1 follows.

-

Installation is in progress.
INSTALL can continue, or it can start over.

-

Message server has previously been installed.
To reinstall the message server, you must enter the maintenance password to initiate the reinstall.
The reinstallation begins by erasing all stored information and messages. Do not use
reinstall unless you are prepared to lose messages.