8-20

Installation and Maintenance Volume

Octel Overture 200/300 Serenade 3.0

PB60014–01

Table 8-2 Hardware Error Types and Remedies (continued)

Error Type:Name

Priority

Remedy

Source

36. System RAM

Error (continued)

Cache module found
an error with system
RAM, CPU and/or
VCU.

Call your technical support center for
remedy.

3

08 =

VCU VOICE RAM < REQUIRED AMOUNT FOR PORT COUNT (SLOT =
FIRST LINE CARD SLOT THAT GOES BEYOND LIMIT FOR EXISTING
RAM)

DATA-2 =

NUMBER MB NEEDED FOR CURRENT PORT
CONFIGURATION

(IF = FF, NUMBER PORTS CONFIGURED > MAX EXPECTED)

DATA-3 =

NUMBER MB REPORTED BY VCU

DATA-4 =

NUMBER PORTS CONFIGURED

09 =

VCU CONTROL RAM INSUFFICIENT FOR LANGUAGES LOADED

DATA-2 =

VCU CONTROL RAM SIZE IN MEGABYTES

DATA-3 =

N/A

DATA-4 =

N/A

10 =

VCU RAM INSUFFICIENT FOR # FAX PORTS CONFIGURED

DATA-2 =

# FAX PORTS SUPPORTED BY VCU RAM

DATA-3 =

VCU CONTROL RAM SIZE IN MEGABYTES

DATA-4 =

VCU VOICE RAM SIZE IN MEGABYTES

11 =

VCU RAM INSUFFICIENT FOR TOTAL NUMBER PORTS CONFIGURED

DATA-2 =

# PORTS SUPPORTED BY VCU RAM

DATA-3 =

VCU CONTROL RAM SIZE IN MEGABYTES

DATA-4 =

VCU VOICE RAM SIZE IN MEGABYTES

12 =

CPU RAM SIZE INSUFFICIENT FOR OCC USER AND PORT COUNTS

DATA-2 =

1 IF ERROR READING OCC
2 IF OCC SIZES TOO LARGE FOR TABLE ALLOCATION

13 =

CPU RAM SIZE INSUFFICIENT FOR LAN OPERATION

DATA-2 =

1 IF ERROR WHILE SYS_ALLOC OPERATION
2 IF ERROR WHILE VRTX PARTITION CREATION

37. Ring Detection

Failure

TEST Line 4

Ensure that the PBX is properly connected
to the LIC, and verify that the PBX type
provides sufficient loop current for the test.
If the PBX is properly connected and the
PBX provides sufficient loop current but
the test still fails, replace the LIC. If the
PBX type does not provide sufficient loop
current, do not use TEST Line 4.

2

DATA-1 =

UNEXPECTED EVENT TYPE

DATA-2 =

NOT USED

DATA-3 =

NOT USED

DATA-4 =

NOT USED