System Errors and Traffic Pegs 8-15

Octel Overture 200/300 Serenade 3.0

PB60014–01

Table 8-2 Hardware Error Types and Remedies (continued)

Error Type:Name

Priority

Remedy

Source

33: Line Card

Hardware Error

Error logged by
selftest when start
LSP reply was
received with either
an error status or an
unexpected OK status
(e.g., Slot is empty or
already reported
down)

Contact your technical support center.

3

The DATA-1 field specifies the type of error. DATA-2 and DATA-3 are data associated
with the error.

DATA-1 =

REPORTED STATUS

00 =

START LSP REPLY RECEIVED WITH EITHER AN ERROR
STATUS OR AN UNEXPECTED OK STATUS

(e.g. slot is empty or already reported down.)

DATA-2 =

REPORTED STATUS

00 =

LSP SUCCESSFULLY STARTED

01 =

SCSI ERROR WHILE LOADING LSP
DATA-4 = VCU ERROR CODE

02 =

CARD TYPE IN SLOT DOES NOT MATCH
CONFIGURED TYPE
DATA-4 =

CARD TYPE ACTUALLY INSTALLED
IN SLOT

03 =

CONTROL BUS ERROR – SLOT EMPTY OR
CARD NON-RESPONSIVE

04 =

FILE SYSTEM READ ERROR ACCESSING LSP
IMAGE

05 =

CARD IN SLOT REPORTS FATAL DIAGNOSTIC
ERROR
DATA-3 =

SUPPLEMENTAL CARD STATUS

06 =

BAD START LSP REQUEST

89 =

LIC REPORTED LIC IMAGE CHECKSUM
ERROR

DATA-3 =

CURRENT SLOT STATE

00 =

EMPTY (UNCONFIGURED)

01 =

WAITING FOR INITIAL START LSP REPLY

02 =

RUNNING

03 =

ERROR

01 =

NO PORTS CONFIGURED FOR LINE CARD

02 =

LINE CARD DISALLOWED BY OCC

03 =

TOTAL PORTS > ALLOWED BY OCC

04 =

ERROR WRITING START LSP REQUEST TO VCU

05 =