Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 501

DTIC 10-9
Octel Overture 200/300 Serenade 3.0
PB60014–01
Modifying a DTIC card in the SLOTS Table is similar to adding a DTIC.
.M SLOT
Enter slot number to MODIFY
Enter empty line when done.
MOD:5
6 –LIC4
2 –SLIC
8 –ACP
7 –DAC4
3 –RIC
17 –FAX4
10 –LIC8
4 –ATTIC
16 –FAX8
11 –TLC8
13 –SIC8
22 –LAN
18 –LIC4I
5 –MITEL
23 –DTC17–E1
26 –DLC16
50 –PICROLM
51 –PICATT
52 –PICNT
33 –ILIC12FR
34 –ILIC12UK
35 –ILIC12JP
37 –ILIC12GR
Enter card type.
SLOT 5:23
Enter LSPTAB table to be referenced for this slot.
0–DEFAULT
1–ILC12_FR
2–ILC12_GE
3–DLC16_US
4–DLC16_AU
5–DLC16_GE
6–ILC12_US
7–DLC16_FR
8–T1
9–MD110–E1
10–DLC16_UK
11–DLC16_UK
12–DLC16_90
49–ACULAB
MOD:9
Should this card be:
(1 – PRIMARY
2 – SECONDARY
3 – TERTIARY
N – no ) sync receiver of the master clock (1–3, N):2
Enter PORT NUMBER to ADD or MODIFY.
Modify port (1 – 30 )
Enter empty line when done.
PORT:1
Enter information for each PORT.
Enter as: EXTENSION NUMBER connected to each port (1–8 digits),
CLASS–OF–SERVICE (0–254), ANSWER MODE (AX, CX, MX), USE PORT FOR MESSAGE
WAITING AND NETWORK OUTCALLING (Y/N)
1 : n,254,ax,n
2 : n
3 : n
.
.
.
28: n
29: n
30: n
.
The number of the ACULAB LSP Table might not be 49, as it is in this example, because this LSP
Table is not part of the Serenade software. If the ACULAB LSP Table does not appear in the list of
LSP Tables, contact Technical Support to add the table and configure it correctly.