8.

Busy out the PBX extension identified in step 6 above.

9.

Continue the process from step 3 until all ports have been busied out.

Testing Fail-Safe Operation

The fail-safe port operation test comprises the all-ports-busy condition and the ring-no-answer condition.

All Ports Busy

Perform the following steps for the all-ports-busy test:

1.

While all ports are busied out, use telephone A to enter the extension number or access code of the
hunt group.

2.

Does the call overflow to the correct answering extension as determined for fail-safe operation?

YES

'

Continue.

NO

'

Determine the cause and correct the problem before continuing.

.

Some PBXs might not support hunt-group overflow; in which case, the caller could
experience a ring no-answer condition until a port is available to accept the call.

3.

Remove the busy condition from all Octel Overture 200/300 port PBX extensions.

Port Ring-No-Answer

Perform the following steps for the port ring-no-answer test:

1.

Disconnect the 25-pair cables associated with the Octel Overture 200/300.

2.

From telephone A, enter the hunt-group extension number or access code associated with the
extensions connected to the Octel Overture 200/300.

3.

Is the call diverted to the correct alternate answer point when the Octel Overture 200/300 does not
answer?

YES

'

Continue.

NO

'

Determine the cause and correct the problem before continuing.

4.

Reconnect the modular line cords.

5.

From the terminal, enter

TE C 1

. The Octel Overture 200/300 should respond, showing that each

port is forwarded until all ports have been forwarded.

6.

Enter

PS

to verify that all ports are in the

FWD

(forwarded) state.

7.

From telephone A, enter the hunt-group extension number or access code.

8.

Is the call forwarded to the correct position as specified in the call forwarding string (System
Parameter 45 — SYSTEM RELOAD FORWARD STRING)?

YES

'

Continue.

NO

'

Determine the cause and correct before continuing.

9.

From the terminal, enter

TE C 2

to cancel call forwarding. The Octel Overture 200/300 should

respond with

ALL PORTS INITIALIZED

.