Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 387
System Errors and Traffic Pegs 8-17
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
34. Power-ON
Diagnostic Error
(continued)
Selftest for integration
cards.
TE INT
LI INT
DATA-1 through
DATA-4 designate
errors found.
Replace integration card as indicated by
slot number.
2
DATA-2
Bit 7:
Error detected on Link 4
Bit 6:
Error detected on Link 3
Bit 5:
Error detected on Link 2
Bit 4:
Error detected on Link 1
Bit 3:
RAM error type 4
Bit 2:
RAM error type 3
Bit 1:
RAM error type 2
Bit 0:
RAM error type 1
DATA-3 =
UNDEFINED
DATA-4 =
UNDEFINED
34. Power-ON
Diagnostic Error
Selftest for CPU.
DATA-1 through
DATA-4 designate
errors found.
Replace CPU. For OCC error, replace
OCC.
3
DATA-1
Bit 7:
5 volts clean out of range
Bit 6:
VCC out of range
Bit 5:
A to D converter error
Bit 4:
PIT1 error
Bit 3:
Parity error
Bit 2:
DRAM data error
Bit 1:
Boot ROM checksum failure
Bit 0:
Fatal CPU error
DATA-2
Bit 7:
DMA page register error
Bit 6:
Unexpected interrupt
Bit 5:
PIT2 (8254) timing error
Bit 4:
Temperature out of range
Bit 3:
-12 volts clean out of range
Bit 2:
-5 volts clean out of range
Bit 1:
12 volts motor out of range
Bit 0:
12 volts clean out of range