beautypg.com

Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 387

background image

System Errors and Traffic Pegs 8-17

Octel Overture 200/300 Serenade 3.0

PB60014–01

Table 8-2 Hardware Error Types and Remedies (continued)

Error Type:Name

Priority

Remedy

Source

34. Power-ON
Diagnostic Error
(continued)

Selftest for integration
cards.

TE INT
LI INT

DATA-1 through
DATA-4 designate
errors found.

Replace integration card as indicated by
slot number.

2

DATA-2

Bit 7:

Error detected on Link 4

Bit 6:

Error detected on Link 3

Bit 5:

Error detected on Link 2

Bit 4:

Error detected on Link 1

Bit 3:

RAM error type 4

Bit 2:

RAM error type 3

Bit 1:

RAM error type 2

Bit 0:

RAM error type 1

DATA-3 =

UNDEFINED

DATA-4 =

UNDEFINED

34. Power-ON

Diagnostic Error

Selftest for CPU.
DATA-1 through
DATA-4 designate
errors found.

Replace CPU. For OCC error, replace
OCC.

3

DATA-1

Bit 7:

5 volts clean out of range

Bit 6:

VCC out of range

Bit 5:

A to D converter error

Bit 4:

PIT1 error

Bit 3:

Parity error

Bit 2:

DRAM data error

Bit 1:

Boot ROM checksum failure

Bit 0:

Fatal CPU error

DATA-2

Bit 7:

DMA page register error

Bit 6:

Unexpected interrupt

Bit 5:

PIT2 (8254) timing error

Bit 4:

Temperature out of range

Bit 3:

-12 volts clean out of range

Bit 2:

-5 volts clean out of range

Bit 1:

12 volts motor out of range

Bit 0:

12 volts clean out of range