Quick reference guide – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 224
R
Quick Reference Guide
Octel Overture 200/300
Maintenance Commands
Octel Overture 200/300 Serenade 3.0
PB60014–01
Section
Information
Command
Subject
Diagnostics
(continued)
List Features
L F
Lists the features, the number of ports, mailboxes,
and storage hours the system is equipped with.
Message Status
L HE x
Lists the status of a message.
x
= message number.
Mailbox
Configuration
L M x
Lists the current configuration for a mailbox.
x
= mailbox number.
Mailbox
Configuration
L M x M
Lists information about messages for a specific
mailbox.
x
= mailbox number; M is a required
extension (the letter M, not an argument) of the
command.
Network Mailbox
Status
L NET x
Displays message information for a network
location.
x
= network location code.
Messages Pending
for Domain
Locations
L NET D [x]
Lists messages pending transfer to the domain in
general or specific domain locations. Messages that
are pending response to LAN queries are also
listed.
x
= is the domain location (optional)
Personal Distribution
List
L PDL
Lists the number of personal distribution list (PDL)
sectors currently used.
Port Configuration
L PO x
Displays information about a port.
x
= port number.
Reports
L R
Gives a menu for the type of report to list.
Integrations
APIC or NPIC
All other integrations
SDBUG xx 1 FF
yy
SDBG xx yy zz
Integration trace information is logged to the
message server’s call-processing trace log file.
where xx is the slot number and yy is either 7F to
turn on debug or 00 to turn off.
where xx is the slot number, yy is the unit number
and zz is either 7F to turn on debug or 00 to turn
off.