Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 616
12-52
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Action
Octel Overture 200/300 Description and Response
To log on to the Octel Overture 200/300.
At the @ prompt enter the slot number for the removed drive. The VCU
tests the slot and updates its status record.
Repeat
DSKTST
for each drive removed.
Views the status of all drive slots.
@
DSKMAP
SLOT: 1 2 3 4 5
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF B| | | System 1 | System 2 | |
| | | ID:S1 ACTIVE | ID: S2 ACTIVE | |
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
SLOT: 1 2 3 4
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF C| Voice 1 | Voice 2 | Voice 3 | Voice 4 |
| ID: UNKNOWN | ID: EMPTY | ID: EMPTY | ID: EMPTY|
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
The following menu is presented:
CURRENT STATUS
Slot
Type ID
Status
Configured
––––––––––––––––––––––––––––
B3
System1
S1
ACTIVE
Configured
B4
System2
S2
ACTIVE
Configured
C1
Voice 1
––
ACTIVE
Configured
DISK OPTIONS
1. ADD DISK
2. REMOVE DISK
3. REPLACE A DISK
4. RESTORE SYSTEM
5. UPGRADE LANGUAGES
Select option to be performed
(1–5 – Empty line = EXIT)
:
After several seconds, the Octel Overture 200/300 displays
Remove drive in slot C1 and repeat DISKO REMOVE command.
8.
Press
Enter
9.
@DSKTST
Enter
10.
@DSKMAP
Enter
Choose the Correct Disk Option
11.
@DISKO
Enter
12. Choose option 2 —
REMOVE DISK
.