Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 372

8-2
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
The boot ROM diagnostic errors and their most likely causes are listed on the following pages. The CPU
error number is displayed in hexdecimal form. A fatal error means that the message server does not come
up.
Table 8-1 Boot ROM Diagnostic Errors
CPU Error
No.
Description
Most Likely
Cause
001
Fatal
Microprocessor instruction set error
CPU
002
Fatal
EPROM checksum error
CPU
003
Fatal
Memory context register error
CPU
004
Fatal
Map RAM pattern test error
CPU
005
Fatal
Map RAM addressing test error
CPU
006
Fatal
DRAM pattern test error
CPU
00A
Fatal
DRAM addressing test error
CPU
00E
Erroneous parity error during DRAM tests
CPU
00F
Erroneous write protect error during DRAM tests
CPU
010
Parity error not detected
CPU
011
Write protect not detected
CPU
012
Data corrupted during write protect test
CPU
013
Z180 CSIO test error
CPU
015
Analog to digital converter test error
CPU
016
+5V VCC out of range (+4.75 to +5.25V)
PSU
017
+5V clear out of range (+4.50V to +5.50V)
PSU
018
+12V clear out of range (+10.8V to +13.2V)
PSU
019
+12V motor out of range (+11.4V to +12.6V)
PSU
01A
Battery out of range (+3.57V to +5.25V)
CPU
01B
Temp out of range (<10 C or >50 C / <50F or >122F)
SYSTEM
01C
Z180 PRT test error
CPU
01D
Fatal
Unexpected NMI error
CPU
01E
Fatal
Unexpected interrupt error
CPU
01F
Z180 DMAC test error
CPU
022
Z180 ASCI test error
CPU
023
Modem loopback test error
CPU
024
TOD RAM pattern or addressing test error
CPU
025
TOD alarm interrupt error
CPU
026
TOD not counting
CPU
027
Floppy disk controller test error
CPU
02B
OCC write error
OCC