System Errors and Traffic Pegs 8-27
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
43. Hard Disk/
Language Table
Read/Write Error
Error detected in the
read/write of language
table
Errors 1 or 3 — Run FLOPPY Backup/
Restore.
Errors 2, 5, 6, 7, or 8 — Run Disk
Exerciser command.
3
DATA-1 =
ERROR CODE, AS FOLLOWS:
01 =
NO LANGUAGE LOADED
02 =
NO ACTIVE SYSTEM DISKS FOR READ
03 =
CK SUM ERROR ON READ
04 =
TABLE SIZE ERR
05 =
CAN’T READ EITHER SYS-DISK
06 =
ERR ON WRITE TO DISK #1
07 =
ERR ON WRITE TO DISK #2
08 =
ERR ON WRITE TO BOTH DISKS
09 =
LANGUAGE QTY LOADED EXCEEDS OCC MAX
44. CPU/VCU
Request/Reply
Checksum Error
A protocol error
occurred between the
CPU and VCU on the
control bus.
Contact your technical support center.
3
DATA-1 =
NUMBER OF RETRIES ATTEMPTED BEFORE TRANSACTION
SUCCEEDED OR ABANDONED (MAXIMUM OF 3).
DATA-2,
DATA-3,
DATA-4 =
FAILURE REASON FOR EACH ATTEMPT:
01 =
NO ERROR (RETRY SUCCEEDED)
02 =
CONTROL BUS TIMEOUT ATTEMPTING TO READ
CPU CB STATUS REGISTER
03 =
CONTROL BUS TIMEOUT ATTEMPTING TO READ
VCU SHARED RAM
04 =
CONTROL BUS TIMEOUT ATTEMPTING TO WRITE
VCU SHARED RAM
05 =
INCORRECT CHECKSUM ON VCU REPLY BUFFER
06 =
VCU DETECTED CHECKSUM ERROR ON CPU
REQUEST BUFFER
45. VCU Reply
Language Set
Error
The VCU has replied
that there is an error in
a language set.
Contact your technical support center.
3
DATA-1
= THIS ERROR NUMBER
DATA-2 — BIT MAP HI BITS= LOAD FAULT
DATA-3 — BIT MAP HI BITS= NOT LOADED