beautypg.com

Hard disk remove – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 615

background image

Procedures 12-51

Octel Overture 200/300 Serenade 3.0

PB60014–01

Hard Disk Remove

This section provides the procedures to follow when removing a drive from a multiple-drive message server. This
procedure applies when you intend to remove a disk without immediately replacing it.

Action

Octel Overture 200/300 Description and Response

Refer to the Hardware Replacement chapter, Hard Disk Drive
Replacement section, for Hard Disk Removal procedures. Hard disks may
be hot plugged.

CPU

Model 300–6004–101

Rev XX

486....

12 MB

......1200 BAUD MODEM.........
BOOTING FROM FLOPPY DISK
..XBOOT...

––––––– SYSTEM SOFTWARE RELEASE X.X.X.X (MM/DD/YY) –––––––
DAY MM/DD HH:MM:SS YYYY ID:000 S/N:000000 PBX:00

(MODEM ENABLED) LAST LOGON: MM/DD HH:MM
@WAITING FOR VCU READY
LOADING VCU WITH FILE F:VCU
VCU STARTED
SYSTEM INITIALIZATION SUSPENDED!
PASSWORD:
@

At this point the Octel Overture 200/300 has completely booted from
floppy diskette.

Remove the Drive(s)

1.

Forward ports.

2.

Remove the hard disk(s) from
the system.

Boot the System

3.

Make sure the software diskette
#1 (for the correct release level)
is write-protected.

4.

Insert software diskette #1 (for
the correct release level) into
the FD.

5.

Adjust the baud rate of the
terminal/teleprinter to 300,
1200, or 9600 baud.

6.

Press the Reload button to boot
from floppy diskette.

7.

Insert diskette #2 when
prompted.