Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 606

12-42
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Example:
@
DSKMAP
SLOT: 1 2 3 4 5
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF B| | | System 1 | System 2 | |
| | | ID:S1 ACTIVE | ID:S2 ACTIVE | |
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
SLOT: 1 2 3 4
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
SHELF C| Voice 1 | Voice 2 | Voice 3 | Voice 4 |
| ID: V1 ACTIVE | ID: EMPTY | ID: EMPTY | ID: EMPTy|
+––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
ID is the status of a drive and can be any of the following:
Status
Explanation
ACTIVE
VALID
INVALID
UNKNOWN
ILLEGAL
ERROR
EMPTY
Drive is valid and currently operating.
Drive is approved for use, but requires rebuild to become active.
Drive configuration is not valid.
Drive configuration is valid, but does not match the rest of the system.
Drive is not an Octel Overture 200/300 drive.
Drive is, or is considered to be, dead.
Drive slot is, or appears to be, empty.
.
OCC MISMATCH
on the screen indicates that the Option Control Chip (OCC) data on the system disk(s) does
not match the OCC data of the system EEPROM. Proper procedures should be followed. Check the Hardware
Error Table to see if the OCC is faulty.
.
ID MISMATCH
on the screen indicates that the drive has previously been installed in a different drive slot. It
must be removed and installed in the correct slot, or a Restore procedure must be performed.
DSKTST
The
DSKTST
utility tests the drive slot specified, updates the last known status record of the VCU, and displays the
status.
DSKTST
can be run from the hard disk or from the software diskette.
Example:
@DSKTST C1
CURRENT STATUS
Slot
Type
ID
Status
––––––––––––––––––––––––––––
C1
Voice1
––
EMPTY
Not Cfgd