Caution – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 448
9-16
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Removing Integration Cards
Use the following procedure to replace an integration card:
1.
Unlock and open the door of the cabinet.
2.
Put on an antistatic wrist strap. Connect it to an unpainted portion of the cabinet.
3.
Use the Courtesy Down command to take the integration card out of service. At the @ prompt, type
CD x y
In this command,
x
is the slot number, and
y
is the unit number.
4.
Disengage the integration card from the motherboard by pivoting the plastic card ejectors at the top
and bottom front edge of the card.
5.
Slide the integration card out of the card cage, handling the card only by the top and bottom edges.
.
Do not touch the components on the card.
6.
Store the removed integration card in a static protection bag.
Installing Integration Cards
Use the following procedure to install an integration card:
1.
Put on an antistatic wrist strap. Connect it to an unpainted portion of the cabinet.
2.
While holding the top and bottom edges of the card, slide it into the card cage.
3.
Pivot the card ejectors, as needed, to grip the small flanges on the front edges of the card cage.
4.
Firmly seat the integration card connectors into the motherboard by pressing the ejectors against the
front edge of the card. The ejector will clip onto small pins on the integration card when the
connectors are seated.
Caution!
Do not slam the integration card into the cabinet, as
this could damage the board or motherboard
connectors.
Once the integration card is installed, the red LED comes ON. When self-test diagnostics are
complete, the green LED comes ON. When the card has been initialized and is ready for operation,
the red LED goes OFF (less than 5 minutes).
5.
Use the Courtesy Up command to initialize the integration card. At the @ prompt, type
CU x y
In this command,
x
is the slot number, and
y
is the unit number.
If there are two units, make sure to initialize both units.
Repeat this step for unit 2.
6.
Test the message server for correct operation.
7.
Close and lock the door to the cabinet.