Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 391

System Errors and Traffic Pegs 8-21
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
38. Disk Defect Boot
Region
Defect in secondary
bootstrap (Xboot)
region
Attempt to reload the software code from
the floppy diskette to the hard disk. If error
repeats, replace the hard disk indicated in
DATA-1. If error repeats again, call your
technical support center.
3
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE XBOOT
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
39. Disk Defect File
System Region
Defect in file system
region of a system
disk
Attempt to reload the software code from
the floppy diskette to the hard disk. If error
repeats, replace the hard disk indicated in
DATA-1. If error repeats, call your
technical support center.
3
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE FILE SYSTEM
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
40. Non-Media Disk
Error
Non-media disk error
Call your technical support center to have
information interpreted.
DATA-1 =
DRIVE ID AND SEVERITY INDICATION
01 =
NON-FATAL ERROR, DRIVE 1
02 =
NON-FATAL ERROR, DRIVE 2
03 =
NON-FATAL ERROR, DRIVE 3
04 =
NON-FATAL ERROR, DRIVE 4
05 =
NON-FATAL ERROR, DRIVE 5
06 =
NON-FATAL ERROR, DRIVE 6
1
81 =
FATAL ERROR, DRIVE 1
82 =
FATAL ERROR, DRIVE 2
83 =
FATAL ERROR, DRIVE 3
84 =
FATAL ERROR, DRIVE 4
85 =
FATAL ERROR, DRIVE 5
86 =
FATAL ERROR, DRIVE 6
3
DATA-2 =
SCSI SENSE KEY
DATA-3 =
SCSI SENSE CODE
DATA-4 =
NOT USED
3