beautypg.com

Test commands – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 234

background image

6-4

Installation and Maintenance Volume

Octel Overture 200/300 Serenade 3.0

PB60014–01

Command

Basic Definition

C H

CLEAR HARDWARE

Clears the Hardware Error Table. Also opens the alarm relay, and turns OFF the
alarm LED.

C I x y

CLEAR INTEGRATION

Clears the integration pegs, where

x

is the slot number and

y

is the unit number.

C P

CLEAR PEG

Clears the Traffic Peg Count Table and the System Performance report.

C NF

CLEAR NETWORK FAILURES

Clears the Network Failure Table, which contains Protocol 2, Protocol 4, Protocol
5, and digital-network errors.

C R

CLEAR REPORT

Gives a menu as follows, for the type of report to clear.

1.

SYSTEM PERFORMANCE (IN TRAFFIC PEGS) AND PORT STATISTICS.

2.

NETWORK TRAFFIC.

3.

USER MESSAGE, USER CALLING AND MAILBOX USAGE.

SELECT REPORT TO BE CLEARED. (1 – 3, EMPTY LINE = EXIT).

C RT 1

CLEAR ROUND TRIP

Clears the round-trip time for message waiting.

Test Commands

The following commands test the status of the LAN card connection, alarm callout, forwarding string,
initializing string, floppy diskette, hard disk, line card, network location, and message server. At the @
prompt, type

TEST

or

TE

, followed by the name of the function to be tested. For example, to test the

alarm, at the @ prompt, type

TE A

Enter

A space is always required between the

TE

(for

TEST

) and the following letter.

Command

Basic Definition

CMD x PING y

For Digital Networking, performs the lowest-level “echo” test from the LAN
card at the local end to the destination server. This is the best tool to use to
identify whether there is end-to-end connectivity across the digital network
between two Octel Overture message servers. It is especially useful to verify that
IP addresses are correctly configured. In the command,

x

is the slot number in

which the LAN card is installed, and

y

is the IP address of the device to which

the test Ethernet packet is sent.

TE A

TEST ALARM

Tests the alarm call out feature. Places a call to the number specified in the
SYSTEM PARAMETER Table — System Parameter 31.