Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 508
10-16
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
The
ST CARD
command shows the status of the card:
dtic>ST CARD
––––– Channel Status – ALL –––––––––––––––––––––––––––––––––––––––––––––––––––––––
CARD STATE:
UP
SEQUENCER PC:
C2
CLOCK MASTER:
Enabled
CLOCK ACTIVE:
Enabled
This example shows normal card status. In this example, the card is enabled to be the synchronization
receiver of the master clock.
The
ST 1
command shows the port status for port 1 (channel 1):
dtic>ST 1
––––– Channel 01 Status ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
RECEIVE
TRANSMIT
ABCD: 0001
ABCD: 0001
OTHER:
CHANNEL STATE:
ON HOOK
SEQUENCER PC:
02
This example shows normal port status for port 1. The port is idle and is transmitting and receiving the
on-hook code.
The
LIST STATS
command gives a count of errors seen by the trunk:
dtic>LIST STATS
ts_oof_cnt
= 0
ts_oof_crc_cnt
= 0
ts_lcv_cnt
= 0
ts_bit_slip_cnt
= 0
ts_crc_fail_cnt
= 0
ts_fas_err_cnt
= 0
ts_febe_cnt
= 0
ts_oof_cas_cnt
= 0
COFA cnt
= 0
CAS COMFA cnt
= 0
HDB3 Detect cnt
= 1
PCM Frm Slip cnt
= 0
The following gives basic information about the fields for these error counts.