beautypg.com

Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 508

background image

10-16

Installation and Maintenance Volume

Octel Overture 200/300 Serenade 3.0

PB60014–01

The

ST CARD

command shows the status of the card:

dtic>ST CARD
––––– Channel Status – ALL –––––––––––––––––––––––––––––––––––––––––––––––––––––––

CARD STATE:

UP

SEQUENCER PC:

C2

CLOCK MASTER:

Enabled

CLOCK ACTIVE:

Enabled

This example shows normal card status. In this example, the card is enabled to be the synchronization
receiver of the master clock.

The

ST 1

command shows the port status for port 1 (channel 1):

dtic>ST 1
––––– Channel 01 Status ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

RECEIVE

TRANSMIT

ABCD: 0001

ABCD: 0001

OTHER:

CHANNEL STATE:

ON HOOK

SEQUENCER PC:

02

This example shows normal port status for port 1. The port is idle and is transmitting and receiving the
on-hook code.

The

LIST STATS

command gives a count of errors seen by the trunk:

dtic>LIST STATS
ts_oof_cnt

= 0

ts_oof_crc_cnt

= 0

ts_lcv_cnt

= 0

ts_bit_slip_cnt

= 0

ts_crc_fail_cnt

= 0

ts_fas_err_cnt

= 0

ts_febe_cnt

= 0

ts_oof_cas_cnt

= 0

COFA cnt

= 0

CAS COMFA cnt

= 0

HDB3 Detect cnt

= 1

PCM Frm Slip cnt

= 0

The following gives basic information about the fields for these error counts.