beautypg.com

Port mapping status, Floppy-disk-drive diagnostics – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 258

background image

6-28

Installation and Maintenance Volume

Octel Overture 200/300 Serenade 3.0

PB60014–01

Port Mapping Status

Use the

PRTMAP

command to display information about the assignment of message-server port numbers

to ports configured in each slot. This command also displays the assignment of each port to an integration
unit. At the @ prompt, type

PRTMAP

Enter

If the PBX type is ATT75, each port can be assigned to more than one integration unit. If the PBX type is
not ATT75, each port can be assigned to only one integration unit and is assigned a line-appearance
number for that integration unit.

If a port is assigned to an integration unit and that port has the COS attribute for nonintegration, Attribute
58 — DO NOT USE THIS PORT FOR INTEGRATION, this command prints

***

after the integration

information for the port. The discrepancy in the configuration must be resolved, either by removing the
COS attribute from the port or removing the port from all integration units.

The following is an example of the

PRTMAP

command without ATT75 assigned:

@PRTMAP
SYSTEM

INTEGRATION

LINE

PORT

SLOT

PORT

EXTN

SLOT/UNIT

APPEARANCE

ID= 0
1

1

1

1210

10/1

1

2

1

2

1211

10/1

2

3

1

3

1212

10/1

3

4

1

4

1213

10/1

4

ID= 0
5

2

1

125

10/1

5

The following is an example of the

PRTMAP

command with ATT75 assigned:

@PRTMAP

SYSTEM

INTEGRATION

PORT

SLOT

PORT

EXTN

SLOT/UNIT

ID= 0

1

1

1

121

10/1 10/2 11/1 11/2

2

1

2

122

10/1 10/2 11/1 11/2

3

1

3

123

10/1

4

1

4

124

10/2

ID= 0

5

2

1

125

10/2

Floppy-Disk-Drive Diagnostics

Use the floppy-disk-drive (FD) diagnostic command

TEST FLOPPY 1

to isolate faults to the diskette,

floppy-disk drive, or floppy-disk controller. To run this test, at the @ prompt, type

TE F 1

Enter