Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
DATA-1 =
FAILURE CODE
:
01 =
INSIDE CABINET TEMPERATURE MEASUREMENT IS OUT OF
RANGE.
10 TO 50 C (50 F TO 122 F)
DATA-2 =
REASON:
01 =
TEMPERATURE TOO HIGH
02 =
TEMPERATURE TOO LOW
02 =
+5 DIGITAL VOLTAGE MEASUREMENT IS OUT OF RANGE
+4.75 TO +5.25
DATA-2 =
REASON:
00 =
VOLTAGE OUT OF RANGE (DIRECTION
UNKNOWN)
01 =
VOLTAGE TOO HIGH
02 =
VOLTAGE TOO LOW
03 =
+12 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
+10.80 TO +13.20
DATA-2 = SAME AS FOR 02
04 =
–12 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
–13.20 TO –10.80
DATA-2 = SAME AS FOR 02
05 =
+12 MOTOR VOLTAGE MEASUREMENT IS OUT OF RANGE
+11.40 TO +12.60
DATA-2 = SAME AS FOR 02
06 =
+5 BATTERY VOLTAGE MEASUREMENT IS OUT OF RANGE
+3.60 TO MINIMUM
DATA-2 = SAME AS FOR 02
0A =
–5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
–5.50 TO –4.50
DATA-2 = SAME AS FOR 02
15: System Status
Error (continued)
Temperature or
voltage out of range
Check DATA-1 for information pertaining
to what is out of range and perform
corrective action.*
3
0B =
+5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
+4.40 TO +5.50
DATA-2 = SAME AS FOR 02
0C =
DISK SHUTDOWN CAUSED BY OUT OF RANGE TEMPERATURE
41 F
to greater than 131 F (5 TO 55 C.)
DATA-2 = REASON
01 =
SUCCESSFUL SHUTDOWN
02 =