Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01

3-62

Revised March, 2012

5) Set Servo Motor Power ON/OFF(servo on/servo off)

Click on the “SVON” button to execute the following procedure:

rt = _DMC_01_ipo_set_svon(gDMCCardNo, NodeID, SlotID , ON_OFF);

// ON_OFF: 0 – Servo Power OFF; 1 – Servo Power ON

6) Start motion control (Using point to point motion control as an example)

Click on the “” or “” button to execute the following procedure:

rt = _DMC_01_start_ta_move(gDMCCardNo, NodeID, SlotID, Distance, StrVel,
MaxVel, acc, dec);

// Motion displacement using absolute coordinates with T-curve

velocity cross-section

7) If you want to change velocity of current motion to a new velocity, you must click on

“V change” to execute the following procedure:

rt = _DMC_01_v_change (CardNo, NodeID, SlotID, NewSpeed, sec);

// Replace current velocity with new velocity

8) Stop motion

Hit the “STOP” button to execute an emergency stop:

rt = _DMC_01_emg_stop (gDMCCardNo, NodeID, SlotID);

In this example, emergency stop is used to stop motion. This method quickly stops
motion by setting deceleration time to 0. For more information about the Stop Motion
function, refer to the later section on “Stop Motion Control API”.

9) Exit procedure

Click on the “Exit” button to quit and exit the procedure.
“_DMC_01_reset_card” and “_DMC_01_close” must be executed to exit this
function. Please refer to Section 3.12 “Exit procedure” for the function operations.