background image

Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01

3-102

Revised March, 2012

1) Card initialization:

Click on the “Initial” button to start card initialization.
For a detailed description of card initialization, please refer to Section 3.1.2 - 1)

Open card.

2) DA Channel and display mode selection

Figure 3.136

Channel item: Enter the ID of the DA Channel to be used (0~3).
Mode item: Select DA display range. API function's argument variable “mode”.
Appro item:
Show approximate voltage or current based on the selected display
range and lever position.
Read item: Display actual output voltage or current.
Apply item: Click on Apply button converts estimated current or voltage from Appro
to actual output.

3) DA Data Choice:

Figure 3.137

Error Handle item: Check this item to keep previous status when re-executing this
program.
Over Range item: Check this item to increase voltage or current output by 10%.
Set Offset item: Set DA offset.
ClearError item:
Clear the Error status indicated by Rtn Code.