Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01

3-6

Revised March, 2012

4) Write servo parameter

Figure 3.10

As shown in Fig. 3.10, if you wish to write a parameter value to servo then you must
input the desired value in the edit box and then click on the “Write” button to execute
the following procedure:

rt = _DMC_01_write_servo_parameter(gDMCCardNo, NodeID, SlotID, group, idx,
data);

//The value will be written to the servo group parameter you set. Please refer to the
previous section for a detailed description.

5) Exit procedure

Click on the “Exit” button to quit and exit the procedure.
“_DMC_01_reset_card” and “_DMC_01_close” must be executed to exit this
function. Please refer to Section 3.12 “Exit procedure” for the function operations.