Chapter 16 Motion Counter Value API | PCI-DMC-A01 / PCI-DMC-B01

Revised March, 2012

16-5

16.6 _DMC_01_get_torque

FORMAT

I16 PASCAL _DMC_01_get_torque (U16 CardNo, U16 NodeID, U16 SlotID, U16* torque)


Purpose

Retrieves and returns the current torque counter value.


Parameters

Name

Data Type

Unit

Description

CardNo U16

Number

Unit CardNo is between 0~15

NodeID

U16

Number Unit Node ID

SlotID

U16

Number Unit Slot ID

torque

U16*

Number

Current torque


Example

U16 CardNo=0;
U16 NodeID =1;
U16 SlotID=0;
U16 torque;

I16 status= _DMC_01_get_torque (CardNo, NodeID, SlotID, &torque);