/* Set AD input range mode*/

rt =_DMC_01_set_04ad_input_range(gDMCCardNo,ADNodeID,SlotID,ChannelAD,

mode);

If the Average option in Fig. 3.139 is selected, execute the following procedure:

/* Set AD waveform output calculation frequency*/

rt =_DMC_01_set_04ad_average_mode(gDMCCardNo,ADNodeID,SlotID,

ChannelAD,mode);

For the Data display in Fig. 3.139, execute the following procedure:

/* Display AD input voltage or current */

rt =_DMC_01_get_04ad_data(gDMCCardNo,ADNodeID,SlotID,ChannelAD,data);

If the Zero option in Fig. 3.140 is selected, execute the following procedure:

/* Reset selected Channel */

rt =_DMC_01_set_04ad_zero_scale(gDMCCardNo,ADNodeID,SlotID,Channel);
rt =_DMC_01_get_04ad_zero_scale_status(gDMCCardNo,ADNodeID,SlotID,

Channel,flag);

/* flag=1 means setup incomplete, flag=0 means setup

completed. */

If the Full option in Fig. 3.140 is selected, execute the following procedure:

/* Adjust maximum value of selected Channel */

rt =_DMC_01_set_04ad_full_scale(gDMCCardNo,ADNodeID,SlotID,Channel);
rt =_DMC_01_get_04ad_full_scale_status(gDMCCardNo,ADNodeID,SlotID,

Channel,flag);

/* flag=1 means setup incomplete, flag=0 means setup

completed. */

8) Exit procedure

Click on the “Exit” button to quit and exit the procedure.
Exit function requires “_DMC_01_reset_card” and _DMC_01_close” to be used. For
a detailed description of these two API please refer to section 3.1.2 4) Exit
procedure.