Delta Electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC-A01 User Manual
Page 492
![background image](/manuals/78362/492/background.png)
Chapter 39 Compare API | PCI-DMC-A01 / PCI-DMC-B01
39-6
Revised March, 2012
39.5 _DMC_01_set_compare_channel_trigger_time
FORMAT
I16 PASCAL _DMC_01_set_compare_channel_trigger_time (U16 CardNo,
U16 compare_channel, U32 time_us)
Purpose
Sets Trigger enable duration.
Parameters
Name
Data Type
Unit
Description
CardNo U16
Number
Unit
CardNo is between 0~15
Compare_channel
U16
Number Unit Channel No is 0~1
Time_us
U32
Time
Enter the duration for each Trigger enable
Example
U16 CardNo = 0;
U16 Compare_channel = 0;
U16 Time_us = 20; //20us
I16 status = _DMC_01_set_compare_channel_trigger_time(CardNo, compare_channel,
time_us);