beautypg.com

Delta Electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC-A01 User Manual

Page 492

background image

Chapter 39 Compare API | PCI-DMC-A01 / PCI-DMC-B01

39-6

Revised March, 2012

39.5 _DMC_01_set_compare_channel_trigger_time

FORMAT

I16 PASCAL _DMC_01_set_compare_channel_trigger_time (U16 CardNo,
U16 compare_channel, U32 time_us)


Purpose

Sets Trigger enable duration.


Parameters

Name

Data Type

Unit

Description

CardNo U16

Number

Unit

CardNo is between 0~15

Compare_channel

U16

Number Unit Channel No is 0~1

Time_us

U32

Time

Enter the duration for each Trigger enable


Example

U16 CardNo = 0;
U16 Compare_channel = 0;
U16 Time_us = 20; //20us

I16 status = _DMC_01_set_compare_channel_trigger_time(CardNo, compare_channel,

time_us);

This manual is related to the following products: