Chapter 30 4-Channel Analog Input Remote I/O Module API | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012
30-7
30.6 _DMC_01_get_04ad_full_scale_status
FORMAT
I16 _DMC_01_get_04ad_full_scale_status (U16 CardNo, U16 NodeID, U16 SlotID,
U16 channelno, U16* status)
Purpose
Checks if AD maximum level calibration is complete.
Parameters
Name
Data Type
Unit
Description
CardNo U16
Number
Unit
CardNo is between 0~15
NodeID
U16
Number Unit
Node ID is (0~12)
SlotID U16
Number
Unit
0
ChannelNo
U16
Number Unit
Channel ID is between 0~3
Status
U16
Selection
0: Zero calibration completed.
1: Zero calibration not completed.
Example
U16 CardNo = 0;
U16 NodeID = 1;
U16 SlotID = 0;
U16 channelno = 0;
U16 status;
I16 status = _DMC_01_get_04ad_full_scale_status (CardNo, NodeID, SlotID, channelno,
&status);