beautypg.com

Delta Electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC-A01 User Manual

Page 132

background image

Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01

3-110

Revised March, 2012

9) Stop motion

Click on the “STOP” button to execute slow down stop for current point to point
motion.

rt = _DMC_01_sd_stop(gDMCCardNo, NodeID, SlotID, dec);

In this example, deceleration is used to stop displacement motion. Here the velocity
is gradually reduced to 0 over the set deceleration time. For a detailed description of
Stop motion, please refer to “Chapter 14 Stop Motion API”.

10) Exit procedure

Click on the “Exit” button to quit and exit the procedure.
Exit function requires “_DMC_01_reset_card” and _DMC_01_close” to be used. For
a detailed description of these two API please refer to section 3.1.2 4) Exit
procedure.