GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 464

GEI-100332Ga
——— PARAMETER LISTS ———
10
70
Parameter
No.
Position
Inversion in 1
1276
I/O CONFIG \ Digital inputs
Inversion in 2
1277
I/O CONFIG \ Digital inputs
Inversion in 3
1278
I/O CONFIG \ Digital inputs
Inversion in 4
1279
I/O CONFIG \ Digital inputs
Inversion in 5
1280
I/O CONFIG \ Digital inputs
Inversion in 6
1281
I/O CONFIG \ Digital inputs
Inversion in 7
1282
I/O CONFIG \ Digital inputs
Inversion in 8
1283
I/O CONFIG \ Digital inputs
Inversion out 1
1267
I/O CONFIG \ Digital outputs
Inversion out 2
1268
I/O CONFIG \ Digital outputs
Inversion out 3
1269
I/O CONFIG \ Digital outputs
Inversion out 4
1270
I/O CONFIG \ Digital outputs
Inversion out 5
1271
I/O CONFIG \ Digital outputs
Inversion out 6
1272
I/O CONFIG \ Digital outputs
Inversion out 7
1273
I/O CONFIG \ Digital outputs
Inversion out 8
1274
I/O CONFIG \ Digital outputs
Inversion relay 2
1275
I/O CONFIG \ Digital outputs
Jog -
399
FUNCTIONS \ Jog function
Jog +
398
FUNCTIONS \ Jog function
Jog operation
265
FUNCTIONS \ Jog function
Jog reference [FF]
266
FUNCTIONS \ Jog function
Jog selection
375
FUNCTIONS \ Jog function
Jog stop control
630
FUNCTIONS \ Stop control
Jog TW enable
1256
OPTIONS \ TORQUE WINDER \ Speed demand
Jog TW speed [%]
1255
OPTIONS \ TORQUE WINDER \ Speed demand
Latch
194
CONFIGURATION \ Prog alarms \ Failure supply
Latch
355
CONFIGURATION \ Prog alarms \ External fault
Latch
357
CONFIGURATION \ Prog alarms \ Undervoltage
Latch
361
CONFIGURATION \ Prog alarms \ Overvoltage
Latch
363
CONFIGURATION \ Prog alarms \ Overcurrent
Latch
471
CONFIGURATION \ Prog alarms \ Field loss
Latch
633
CONFIGURATION \ Prog alarms \ Bus loss
Latch
729
CONFIGURATION \ Prog alarms \ Enable seq err
Latch
1421
CONFIGURATION \ Prog alarms \ Overspeed
Latch
1433
CONFIGURATION \ Prog alarms \ Delta frequency
Latch
1442
CONFIGURATION \ Prog alarms \ Motor I2t ovrld
Life time [h.min]
235
SPEC FUNCTIONS
Line acc [%]
1184
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line acc status
1188
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line dec [%]
1185
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line dec status
1189
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line fast stop [%]
1186
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line fstp status
1190
OPTIONS \ TORQUE WINDER \ Torque calculat \ Comp calculat
Line spd source
1204
OPTIONS \ TORQUE WINDER \ Diam Calculatio
Line speed [%]
1160
OPTIONS \ TORQUE WINDER \ Diam Calculatio
Line speed gain
1156
OPTIONS \ TORQUE WINDER \ Diam Calculatio
Load comp [%]
698
SPEED REGULAT \ Droop function
Load default
258
SPEC FUNCTIONS
Lock speed I
348
SPEED REGULAT
Lock speed reg
322
SPEED REGULAT
Main commands
252
START UP
Main commands
252
REG PARAMETERS \ In use values
Mains frequency [Hz]
588
MONITOR \ Measurements