GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
14
Enable drive
When the converter is controlled via the keypad, it is activated via the Enable drive parameter.
A voltage is also required on terminal 12. The Start command is required for starting
the drive.
Enabled
Enable drive
Disable
Drive disabled
Start/Stop
Using the keypad as Start/Stop control, if Enter key is pushed, the motor run at the speed
set.
Ramp red (d)
Total reference value for the ramp in units specified by the factor function.
Ramp ref (rpm)
Total reference value for the ramp in rpm
Ramp ref (%)
Total reference value for the ramp as a percentage of the Speed base value.
Ramp output (d)
Ramp output in units specified by the factor function.
Ramp outp (rpm)
Ramp output in rpm
Ramp output (%)
Ramp output as a percentage of the Speed base value
Speed ref (d)
Total speed reference value in units specified by the factor function.
Speed ref (rpm)
Total speed reference value in rpm
Speed ref (%)
Total speed reference value as a percentage of the Speed base value
Actual spd (d)
Actual speed in units specified by the factor function.
Actual spd (rpm)
Actual speed in rpm (revolutions per minute).
Actual spd (%)
Actual speed as a percentage of the Speed base value
F act spd (d)
Filtered value of Actual speed in units specified by the factor function.
F act spd (rpm)
Filtered value of Actual speed in rpm..
Act spd filter
1
st
order low pass filter time constant on Actual speed.
Enc 1 speed (rpm)
Actual speed measured by the encoder 1. The parameter is accessible only if the
Speed fbk sel = encoder 2 and a digital encoder is used as encoder 1
(interfacing with the drive by means of the 6KKDV300DES card).
Enc. 2 speed (rpm)
Actual speed measured by the encoder 2. The parameter is accessible only if
Spees bfk sel = encoder 2
Mains voltage
Mains voltage in V
Mains frequency
AC input frequency in Hz
Output power
Output power value in Kw
Output voltage
Armature Voltage U
dA
in V
AV
Motor current
Armature current in % of Full load curr.
F T curr (%)
Filtered value of Torque current in percentage.
T curr filter
1
st
order low pass filter time constant on Torque current.
T current ref
Total current reference value as a percentage of the Full load current
Flux reference
Field current (reference) as a percentage of Motor nom flux.
Flux curr (%)
Actual field current value as percentage of Motor nom flux.
Flux curr (A)
Actual field current value in amps.
Digital I/O
Status of the digital input and output of the base converter and the card
6KCV300TBO.
Display:
I 1 2 3 4 5 6 7 8 E S F
Q 1 2 3 4 5 6 7 8
An I/O is displayed only if a voltage is present on the corresponding terminal. E.g.,
if the inputs 4 and 6 are displayed, that means that the digital inputs 4 and 6 on the