GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 406

GEI-100332Ga
——— PARAMETER LISTS ———
10
12
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
FLUX REGULATION (FIELD CURRENT REGULATION) \ Flux \ if curve
I field cnst 40
916
Float
0.0
100.0
40.0
40.0
ü
R/Z
-
I field cnst 70
917
Float
0.0
100.0
70.0
70.0
ü
R/Z
-
I field cnst 90
918
Float
0.0
100.0
90.0
90.0
ü
R/Z
-
Set flux / if
919
U16
0
1
0
0
ü
Z/C
-
Reset flux / if
920
U16
0
1
0
0
ü
Z/C
-
Nom flux curr [A]
(Field curr scale [A])
374
Float
0.5
70.0
S
S
ü
R/Z
-
-
Motor nom flux
(Motor field curr [A])
280
Float
0.00
P374
P374
P374
ü
R/Z
-
-
REG PARAMETERS \ Percent values \ Speed regulator
Speed P [%]
87
Float
0.00
100.00
10.00
10.00
ü
R/W
-
-
Speed I [%]
88
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
Speed P bypass [%]
459
Float
0.00
100.00
10.00
10.00
ü
R/W
-
-
Speed I bypass [%]
460
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
REG PARAMETERS \ Percent values \ Flux regulator ( Field regulator)
Flux P [%]
(Fld reg P gain [%])
91
Float
0.00
100.00
2.00
2.00
ü
R/W
-
-
Flux I [%]
(Fld reg I gain [%])
92
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
REG PARAMETERS \ Percent values \ Voltage reg
Voltage P [%]
493
Float
0.00
100.00
30.00
30.00
ü
R/W
-
-
Voltage I [%]
494
Float
0.00
100.00
40.00
40.00
ü
R/W
-
-
REG PARAMETERS \ Base values \ Speed regulator
Speed P base [A/rpm]
93
Float
000.1
S
0.3 x
P93max
P93max
0.3 x
P93max
P93max
ü
R/Z
-
-
Speed I base [A/rpm·ms]
94
Float
0.001
S
0.3
P94max
0.3
P94max
ü
R/Z
-
-
REG PARAMETERS \ Base values \ Flux regulator (Field regulator)
Flux P base
(Fld reg PG base)
97
Float
1
32767
3277
3277
ü
R/Z
-
-
Flux I base
(Fld reg IG base)
98
Float
1
32767
3277
3277
ü
R/Z
-
-
REG PARAMETERS \ Base values \ Voltage reg
Voltage P base [f%/V]
495
Float
0.0100
S
S
S
ü
R/Z
-
-
Voltage I base [f%/V·ms]
496
Float
0.01
S
S
S
ü
R/Z
-
-
REG PARAMETERS \ In use values
Speed P in use [%]
99
Float
0.00
100.00
S
S
ü
R
-
-
Speed I in use [%]
100
Float
0.00
100.00
S
S
ü
R
-
-
CONFIGURATION
Main commands
Terminals
Digital
252
U16
0
1
Term.(0)
Term.(0)
ü
R/Z
0
1
-
-
Control mode
Local
Bus
253
U16
0
1
Local (0) Local (0)
ü
R/Z
0
1
-
-
Speed base value [FF]
45
U32***
1
16383
1500
1500
ü
R/Z
-
R
Full load curr [A]
179
Float
0.1
P465
P465
P465
ü
R/Z
-
-
Max out voltage [V]
175
Float
20
999
400
400
ü
R/Z
-
-
Ok relay funct
Drive healthy
Ready to Start
412
I16
0
1
0
0
ü
R/Z
0
1
-
-
CONFIGURATION \ Speed fbk
Motor max speed [rpm]
162
Float *
0
6553
1500
1500
ü
R/Z
-
R