GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 220

GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
92
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Enab multi spd
Enabled (1)
Disabled (0)
153
0
1
Disabled
Disabled
Multi speed 1 [FF]
154
-32768
+32767
0
0
-
Multi speed 2 [FF]
155
-32768
+32767
0
0
-
Multi speed 3 [FF]
156
-32768
+32767
0
0
-
Multi speed 4 [FF]
157
-32768
+32767
0
0
-
Multi speed 5 [FF]
158
-32768
+32767
0
0
-
Multi speed 6 [FF]
159
-32768
+32767
0
0
-
Multi speed 7 [FF]
160
-32768
+32767
0
0
-
Speed sel 0
Value 2
0
not selected (0)
Value 2
0
selected (1)
400
0
1
0
0
Digital inp 5 *
Speed sel 1
Value 2
1
not selected (0)
Value 2
1
selected (1)
401
0
1
0
0
Digital inp 6 *
Speed sel 2
Value 2
2
not selected (0)
Value 2
2
selected (1)
402
0
1
0
0
Digital inp 7 *
Multispeed sel
208
0
7
0
0
* This function can be assigned to one of the programmable digital inputs.
Enab multi spd
Enabled
Enabled multi speed function
Disabled
Disabled multi speed function
Multi speed 1
Reference value 1 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 2
Reference value 2 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 3
Reference value 3 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 4
Reference value 4 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 5
Reference value 5 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 6
Reference value 6 for enabled multi speed function. Defined by the units specified in
the factor function
Multi speed 7
Reference value 7 for enabled multi speed function. Defined by the units specified in
the factor function
Speed sel 0
Reference value selection with the significance 2
0
(=1) (Bit 0). Parameter can only be
used in conjunction with Speed sel 1 and Speed sel 2.
High
Significance 2
0
selected
Low
Significance 2
0
not selected
Speed sel 1
Reference value selection with the significance 2
1
(=2) (Bit 1). Parameter can only be
used in conjunction with Speed sel 0 and Speed sel 2.
High
Significance 2
1
selected
Low
Significance 2
1
not selected
Speed sel 2
Reference value selection with the significance 2
2
(=4) (Bit 2). Parameter can only be
used in conjunction with Speed sel 0 and Speed sel 1.
High
Significance 2
2
selected
Low
Significance 2
2
not selected
Multi speed sel
It is the word representation of the three parameters Speed sel 1 (bit0), Speed sel 2 (bit1)
and Speed sel 3 (bit2). Used to change the speed selection by changing only one pa-
rameter instead of three. This allows selecting different speeds via serial line or Bus
instantaneously.