Page 136: First basic setting, Motor data

GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
8
6.2 BASIC START up MENuS
The following DRIVE STATUS, START UP and TUNING allow a basic commissioning of the drive.
n
ote
!
The parameters in these menus are available in other menus.
See Start up procedure on chapter 5.4 for commissioning information.
DRIVE STATuS
Menu displayed at power up.
Status parameters of the drive are available and Ramp ref 1 parameter for basic speed reference with ramp
time.
START up
In this menu the start up sequencing is available.
First basic setting
Speed base value
Speed base value is defined by the unit in the factor function specified. It is the reference
value for all the speed reference values (reference values, adaptive speed regulation)
given as a percentage, and corresponds to 100% of the speed. Changing this parameter is
only possible when the drive is disabled (Enable drive=Disable). The speed base value
does not define the maximum possible speed, which in some cases can be formed from
the addition of several reference values. This is defined with Speed max amount.
Nom flux curr
Drive field current value.
Speed-0 f weak
Enables the field economy at zero speed.
Acc / Dec ...
Acceleration and deceleration ramp time setting on the speed reference.(see chapter
6.6.1 for more details).
Motor data
Motor plate data:
Motor nom flux
Motor field current in Amps.
Flux reg mode
Field regulator mode.
Full load curr
Nominal motor current in Amps
Motor max speed
Maximum motor speed value
Max out voltage
Maximum armature voltage value
Flux weak speed
Motor max speed percentage where the flux weakening range starts. (Crossover
point)