3 digital outputs – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 201

DV-300 Adjustable Speed Drives
——— FUNCTION DESCRIPTION ———
6
73
Example 5:
Select input 1 to T current lim
10Volt or 20 mA on Analog input 1 corresponds to T current lim = 100 [%]
The application requires a signaling at 50 [%] via a digital output, with a tolerance band equal to ±2 [%]
Input 1 cp match assigned to a programmable digital output
Input 1 compare = 50 * 10000 / 100 = 5000
Input 1 cp error = 2 * 10000 / 100 = 200
6.12.3 Digital Outputs
I/O CONFIG
Digital outputs
[145]
Digital output 1
[1267]
Inversion out 1
[146]
Digital output 2
[1268]
Inversion out 2
[147]
Digital output 3
[1269]
Inversion out 3
[148]
Digital output 4
[1270]
Inversion out 4
[149]
Digital output 5
[1271]
Inversion out 5
[150]
Digital output 6
[1272]
Inversion out 6
[151]
Digital output 7
[1273]
Inversion out 7
[152]
Digital output 8
[1274]
Inversion out 8
[629]
Relay 2
[1275]
Inversion relay 2
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Digital output 1
145
0
77
Ramp + (8)
Ramp + (8)
Inversion out 1
Enabled (1) / Disabled (0)
1267
0
1
Disabled (0)
Disabled (0)
Digital output 2
146
0
77
Ramp - (9)
Ramp - (9)
Inversion out 2
Enabled (1) / Disabled (0)
1268
0
1
Disabled (0)
Disabled (0)
Digital output 3
147
0
77
Spd thr. (2)
Spd thr. (2)
Inversion out 3
Enabled (1) / Disabled (0)
1269
0
1
Disabled (0)
Disabled (0)
Digital output 4
148
0
77
Overld avail. (6)
Overld avail. (6)
Inversion out 4
Enabled (1) / Disabled (0)
1270
0
1
Disabled (0)
Disabled (0)
Digital output 5
149
0
77
Curr lim. state (4)
Curr lim. state (4)
Inversion out 5
Enabled (1) / Disabled (0)
1271
0
1
Disabled (0)
Disabled (0)
Digital output 6
150
0
77
Over-voltage (12)
Over-voltage (12)
Inversion out 6
Enabled (1) / Disabled (0)
1272
0
1
Disabled (0)
Disabled (0)
Digital output 7
151
0
77
Under-voltage (11) Under-voltage (11)
Inversion out 7
Enabled (1) / Disabled (0)
1273
0
1
Disabled (0)
Disabled (0)
Digital output 8
152
0
77
Over-current (14)
Over-current (14)
Inversion out 8
Enabled (1) / Disabled (0)
1274
0
1
Disabled (0)
Disabled (0)
Relay 2
629
0
77
Stop ctrl (23)
Stop ctrl (23)
Inversion relay 2
Enabled (1) / Disabled (0)
1275
0
1
Disabled (0)
Disabled (0)