Final operation, Tuning, Current self tuning – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 139: Speed self tune

DV-300 Adjustable Speed Drives
——— FUNCTION DESCRIPTION ———
6
11
Final operation
(See chapter 6.11.1 for more parameters detail).
Main commands
This command specifies from where the Enable drive and Start command has to be
actuated.
Control mode
Defines whether the digital channel is the keypad/RS485 or Fieldbus card.
Save parameters
Saving of user parameters value setting
TuNING
This menu allows a fine manual tuning of the drive regulators.
Current self tuning
Current regulator self tuning procedure via R&L Search (as indicate in START UP menu).
Speed self tune
Speed regulator self tune procedure (as indicate in START UP\ Speed self tune menu).
Manual tuning of speed regulator, field regulator and voltage regulator
Manual tuning of the drive regulators (see chaper 5.3.6 for other details) :
Speed P
Proportional coefficient of the speed regulator in percentage
Speed I
Integral coefficient of the speed regulator in percentage.
Prop filter
Time constant filter to the proportional coefficient of the speed regulator
Flux P
Proportional coefficient of the field regulator in percentage.
Flux I
Integral coefficient of the field regulator in percentage
Voltage P
Proportional coefficient of the voltage regulator in percentage.
Voltage I
Integral coefficient of the voltage regulator in percentage
Save parameters
Saving of user parameters value setting