10
47
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Failure register
330
U16
1
10
10
10
ü
R/W
-
-
Software version
331
Text
ü
R
-
-
Torque reduct
Not active
Active
342
U16
0
1
Not active
(0)
Not active
(0)
ü
R/W
0
1
ID
L
H
R/W
0
1
Quick stop
Quick stop
No Quick stop
343
U16
0
1
No Quick
stop
No Quick
stop
-
R/W
0
1
-
-
Ramp out = 0
Active
Not active
344
U16
0
1
Not active
(1)
Not active
(1)
ü
R/W
0
1
ID
L
H
R/W
0
1
Ramp in = 0
Active
Not active
345
U16
0
1
Not active
(1)
Not active
(1)
ü
R/W
0
1
ID
L
H
R/W
Ramp +
Acc.CW + Dec. anti-CW
(Acc.clockwise + Dec. anti-
clockwise)
Other states
346
U16
0
1
-
-
-
R
1
0
QD
H
L
R
1
0
Ramp -
Acc.anti-CW + Dec. CW
(Acc.anti-clockwise + Dec.
Clockwise)
Other states
347
U16
0
1
-
-
-
R
1
0
QD
H
L
R
1
0
Lock speed I
Active
Not active
348
U16
0
1
Not active
(1)
Not active
(1)
ü
R/W
0
1
ID
L
H
R/W
0
1
Curr limit state
Curr. limit not reached
Curr. limit reached
349
U16
0
1
-
R
0
1
QD
L
H
R
0
1
Flux current (A)
(Field curr amps (A))
351
Float
0.1
99.9
S
S
ü
R
-
-
Zero torque
Active
Not active
353
U16
0
1
Not ac-
tive
(1)
Not ac-
tive
(1)
ü
R/W
0
1
ID
L
H
R/W
Activity
Warning
Disable drive
Quick stop
Normal stop
Curr lim stop
354
U16
1
5
Disable
drive
Disable
drive
ü
R/Z
1
2
3
4
5
-
-
Latch
ON
OFF
355
U16
0
1
ON
ON
ü
R/Z
1
0
-
-
Ok relay open
ON
OFF
356
I16
0
1
ON
ON
ü
R/W
1
0
-
-
Latch
ON
OFF
357
U16
0
1
ON
ON
ü
R/Z
1
0
-
-
Ok relay open
ON
OFF
358
I16
0
1
ON
ON
ü
R/W
1
0
-
-
Restart time [ms]
359
U16
0
65535
1000
1000
ü
R/W
-
-
Latch
ON
OFF
361
U16
0
1
ON
ON
ü
R/Z
1
0
-
-