GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 223

DV-300 Adjustable Speed Drives
——— FUNCTION DESCRIPTION ———
6
95
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Enab multi rmp
Enabled (1) / Disabled (0)
243
0
1
Disabled
Disabled
-
Ramp selector
202
0
3
0
0
-
Acc delta speed0 [FF]
659
0
232-1
100
100
-
Acc delta time 0 [s]
660
0
65535
1
1
-
S acc t const 0 [ms]
665
100
3000
300
300
Dec delta speed0 [FF]
661
0
232-1
100
100
-
Dec delta time 0 [s]
662
0
65535
1
1
-
S dec t const 0 [ms]
666
100
3000
300
300
Acc delta speed1 [FF]
23
0
232-1
100
100
-
Acc delta time 1 [s]
24
0
65535
1
1
-
S acc t const 1 [ms]
667
100
3000
300
300
Dec delta speed1 [FF]
31
0
232-1
100
100
-
Dec delta time 1 [s]
32
0
65535
1
1
-
S dec t const 1 [ms]
668
100
3000
300
300
Acc delta speed2 [FF]
25
0
232-1
100
100
-
Acc delta time 2 [s]
26
0
65535
1
1
-
S acc t const 2 [ms]
669
100
3000
300
300
Dec delta speed2 [FF]
33
0
232-1
100
100
-
Dec delta time 2 [s]
34
0
65535
1
1
-
S dec t const 2 [ms]
670
100
3000
300
300
Acc delta speed3 [FF]
27
0
232-1
100
100
-
Acc delta time 3 [s]
28
0
65535
1
1
-
S acc t const 3 [ms]
671
100
3000
300
300
Dec delta speed3 [FF]
35
0
232-1
100
100
-
Dec delta time 3 [s]
36
0
65535
1
1
-
S dec t const 3 [ms]
672
100
3000
300
300
Ramp sel 0
Value 2
0
not selected (0)
Value 2
0
selected (1)
403
0
1
0
0
*
Ramp sel 1
Value 2
1
not selected (0)
Value 2
1
selected (1)
404
0
1
0
0
*
* This function can be assigned to one of the programmable digital inputs.
Enab multi rmp
Enabled
The Multi ramp function is enabled
Disabled
The Multi ramp function is disabled
Ramp selector
It is the word representaton of the two parameters Ramp sel 0 (bit0) and Ramp sel 1
(bit1). Used to change the ramp selection by changing only one parameter instead of
two. This allows to select different ramps via serial line or Bus instantaneously.
Acc delta speed 0
It defines together with Acc delta time 0 the acceleration ramp 0. Defined by the units
specified in the factor function.
Acc delta time 0
It defines together with Acc delta speed 0 the acceleration ramp 0. Defined in seconds.
S acc t const 0
Defines the acceleration curve for S-shape ramp 0. Defined in ms.
Dec delta speed0
It defines together with Dec delta time 0 the deceleration ramp 0. Defined by the units
specified in the factor function.
Dec delta time 0
It defines together with Acc delta speed 0 the acceleration ramp 0. Defined in seconds.
S dec t const 0
Defines the deceleration curve for S-shape ramp 0. Defined in ms.
Acc delta speed1
It defines together with Acc delta time 1 the acceleration ramp 1. Defined by the units
specified in the factor function.