6

184

Constant J comp

Compensation of the fixed section (motor, reducer,pin) as a percentage of the drive rated

current. As for tuning see the paragraph Application example.

Act var J comp

Monitor for the active compensation of the variable section as a percentage of the drive

rated current.

Act const J comp

Monitor for the active compensation of the fixed section as a percentage of the drive

rated current.

Mat width

Width of the wound material as a percentage of the maximum width.

Static f

Compensation of the static frictions as a percentage of the drive rated current. As for

tuning see the paragraph Application example.

Dinamic f

Compensation of the dynamic frictions as a percentage of the drive rated current. As

for tuning see the paragraph Application examples.

Static f Zero

By setting the parameter on “Enabled”, the friction compensation is completely inserted

for all speed values. When it set as “Disabled”, the static friction compensation is com-

pletely inserted with Ref line speed = 1.5%.

Act comp

Monitor for the active compensations (it sums up the static, dynamic and inertial fric-

tions) as a percentage of the drive rated current.

Closed loop En

Enabling of the tension loop closing (to be used with a loading cell).

Closed loop comp

Monitor for the active compensation, output of the PID regulator used for the loop

closing.