184
Constant J comp
Compensation of the fixed section (motor, reducer,pin) as a percentage of the drive rated
current. As for tuning see the paragraph Application example.
Act var J comp
Monitor for the active compensation of the variable section as a percentage of the drive
rated current.
Act const J comp
Monitor for the active compensation of the fixed section as a percentage of the drive
rated current.
Mat width
Width of the wound material as a percentage of the maximum width.
Static f
Compensation of the static frictions as a percentage of the drive rated current. As for
tuning see the paragraph Application example.
Dinamic f
Compensation of the dynamic frictions as a percentage of the drive rated current. As
for tuning see the paragraph Application examples.
Static f Zero
By setting the parameter on “Enabled”, the friction compensation is completely inserted
for all speed values. When it set as “Disabled”, the static friction compensation is com-
pletely inserted with Ref line speed = 1.5%.
Act comp
Monitor for the active compensations (it sums up the static, dynamic and inertial fric-
tions) as a percentage of the drive rated current.
Closed loop En
Enabling of the tension loop closing (to be used with a loading cell).
Closed loop comp
Monitor for the active compensation, output of the PID regulator used for the loop
closing.