GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 438

GEI-100332Ga
——— PARAMETER LISTS ———
10
44
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Digital output 3
(Select like output 1)
147
U16
0
77
Spd thr.
(2)
Spd thr.
(2)
ü
R/Z
-
-
Digital output 4
(Select like output 1)
148
U16
0
77
Overld
avail. (6)
Overld
avail. (6)
ü
R/Z
-
-
Digital output 5
(Select like output 1)
149
U16
0
77
Curr lim.
state (4)
Curr lim.
state (4)
ü
R/Z
-
-
Digital output 6
(Select like output 1)
150
U16
0
77
Over-
voltage
(12)
Over-
voltage
(12)
ü
R/Z
-
-
Digital output 7
(Select like output 1)
151
U16
0
77
Under-
voltage
(11)
Under-
voltage
(11)
ü
R/Z
-
-
Digital output 8
(Select like output 1)
152
U16
0
77
Over-cur-
rent (14)
Over-cur-
rent (14)
ü
R/Z
-
-
Enab multi spd
Enabled
Disabled
153
I16
0
1
Disabled
Disabled
ü
R/Z
1
0
-
-
Multi speed 1 [FF]
154
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 2 [FF]
155
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 3 [FF]
156
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 4 [FF]
157
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 5 [FF]
158
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 6 [FF]
159
I16
-32768
+32767
0
0
ü
R/W
-
-
Multi speed 7 [FF]
160
I16
-32768
+32767
0
0
ü
R/W
-
-
Motor max speed [rpm]
162
Float *
0
6553
1500
1500
ü
R/Z
-
R
Encoder 2 pulses
169
Float *
600
9999
1024
1024
ü
R/Z
-
R
Max out voltage [V]
175
Float
20
999
400
400
ü
R/Z
-
-
Full load curr [A]
179
Float
0.1
IdAN
IdAN
IdAN
ü
R/Z
-
-
Enable spd adap
Enabled
Disabled
181
U16
0
1
Disabled
Disabled
ü
R/Z
1
0
-
-
Select adap type
Speed
Adap reference
Parameter
182
U16
0
2
Speed
Speed
ü
R/Z
0
1
2
-
-
Adap reference [FF]
183
I16
-32768
+32767
1000
1000
ü
R/W
IA
R/W
Adap speed 1 [%]
184
Float
0.0
200.0
20.3
20.3
ü
R/W
-
-
Adap speed 2 [%]
185
Float
0.0
200.0
40.7
40.7
ü
R/W
-
-
Adap joint 1 [%]
186
Float
0.0
200.0
6.1
6.1
ü
R/W
-
-
Adap joint 2 [%]
187
Float
0.0
200.0
6.1
6.1
ü
R/W
-
-
Adap P gain 1 [%]
188
Float
0.00
100.00
10.00
10.00
ü
R/W
-
-
Adap I gain 1 [%]
189
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
Adap P gain 2 [%]
190
Float
0.00
100.00
10.00
10.00
ü
R/W
-
-
Adap I gain 2 [%]
191
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
Adap P gain 3 [%]
192
Float
0.00
100.00
10.00
10.00
ü
R/W
-
-
Adap I gain 3 [%]
193
Float
0.00
100.00
1.00
1.00
ü
R/W
-
-
Latch
ON
OFF
194
U16
0
1
ON
ON
ü
R/Z
1
0
-
-
Ok relay open
ON
OFF
195
I16
0
1
ON
ON
ü
R/W
1
0
-
-
Motor current [%]
199
I16
-250
250
-
-
ü
R
QA
R