1 compensations and closing of the tension loop – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 310

GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
182
6.17.2.1 Compensations and closing of the tension loop
OPTIONS
Torque winder
Torque calculat
Comp calculat
[1183]
Int acc calc En
[1182]
Time acc/dec min [s]
[1212]
Acc/dec filter [ms]
[1184]
Line acc [%]
[1185]
Line dec [%]
[1186]
Line fast stop [%]
[1188]
Line acc status
[1189]
Line dec status
[1190]
Line fstp status
[1171]
Variable J comp [%]
[1172]
Constant J comp [%]
[1192]
Act var J comp [%]
[1191]
Act const J comp [%]
[1173]
Mat width [%]
[1174]
Static f [%]
[1175]
Dinamic f [%]
[1287]
Static f Zero
[1213]
Actual comp [%]
[1214]
Closed loop En
[1208]
Close loop comp
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Int acc calc En
Enabled (1) / Disabled (0)
1183
0
1
Enabled (1)
Enabled (1)
*
Time acc/dec min [s]
1182
0.15
300.00
9.01
9.01
Acc/dec filter [ms]
1212
0
5000
30
30
Line acc [%]
1184
0.00
100.00
100
100
Line dec [%]
1185
0.00
100.00
100
100
Line fast stop [%]
1186
0.00
100.00
100
100
Line acc status
1188
0
1
OFF
OFF
*
Line dec status
1189
0
1
OFF
OFF
*
Line fstp status
1190
0
1
OFF
OFF
*
Variable J comp [%]
1171
0.00
199.99
0
0
Constant J comp [%]
1172
-100.00 +100.00
0
0
Act var J comp [%]
1192
-
200.00
0
0
Act const J comp [%]
1191
-
200.00
0
0
Mat width [%]
1173
0.00
100.00
100
100
Static f [%]
1174
0.00
199.99
0
0
Dinamic f [%]
1175
0.00
199.99
0
0
Static f Zero
Enabled (1) / Disabled (0)
1287
0
1
Disabled (0)
Disabled (0)
Actual comp [%]
1213
-200
+200
**
Closed loop En
Enabled (1) / Disabled (0)
1214
0
1
Disabled (0)
Disabled (0)
Close loop comp
1208
-32767
+32767
*
This parameter can be set on a programmable digital input.
** This parameter can be set on a programmable digital output.