1 analog ouputs – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 193

DV-300 Adjustable Speed Drives
——— FUNCTION DESCRIPTION ———
6
65
When other digital inputs/outputs and/or analog outputs are required, together with the already existing ones,
the TBO option card has to be used, which is inserted on the converter regulation card. A converter card can
also be mounted (see figure):
- with TBO “B” (6KCV300TBO) option card:
Option “B”:
2 Analog outputs (3 and 4) with common reference point
4 Digital outputs (5 ...8) with common reference point and common voltage supply
4 Digital inputs (5...8) with common reference point.
n
ote
!
If parameters are assigned to particular terminals, the parameter value (e.g. speed reference
value) can only be entered via this terminal and not via the keypad or bus.
6.12.1 Analog Ouputs
I/O CONFIG
Analog outputs
Analog output 1
[66]
Select output 1
[62]
Scale output 1
Analog output 2
[67]
Select output 2
[63]
Scale output 2
Analog output 3
[68]
Select output 3
[64]
Scale output 3
Analog output 4
[69]
Select output 4
[65]
Scale output 4
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Select output 1
66
0
94
Actual speed (8)
Actual speed (8)
Scale output 1
62
Float
-10.000
+10.000
0.000
0.000
Select output 2
67
0
94
Motor current (16)
Motor current (16)
Scale output 2
63
-10.000 +10000
0.000
0.000
Select output 3
68
0
94
Flux
-27
Flux
-27
*
Scale output 3
64
-10.000 +10000
0.000
0.000
Select output 4
69
0
94
Output voltage (20)
Output voltage (20)
*
Scale output 4
65
-10.000 +10000
0.000
0.000
*
6KCV300TBO option card (TBO “B”) has to be installed.
Select output XX
Selection of the parameter assigned as a variable to the corresponding analog output.
The following assignments are possible: