DV-300 Adjustable Speed Drives
——— FUNCTION DESCRIPTION ———
6
13
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Enable drive
Enabled (1)
Disabled (0)
314
0
1
Disabled
Disabled
Terminal 12
+15 ... 30 V
0 V
Start/Stop
Start (1)
Stop (0)
315
0
1
Stop (0)
Stop (0)
Terminal 13
+15 ... 30 V
0 V
Ramp ref (d) [FF]
109
-32768
+32767
-
-
-
Ramp ref (rpm)
110
-32768
+32767
-
-
*
Ramp ref (%)
111
-200.0
+200.0
-
-
-
Ramp output (d) [FF]
112
-32768
+32767
-
-
-
Ramp outp (rpm)
113
-32768
+32767
-
-
*
Ramp output (%)
114
-200.0
+200.0
-
-
-
Speed ref (d) [FF]
115
-32768
+32767
-
-
-
Speed ref (rpm)
118
-32768
+32767
-
-
*
Speed ref (%)
117
-200.0
+200.0
-
-
-
Actual spd (d) [FF]
119
-32768
+32767
-
-
-
Actual spd (rpm)
122
-8192
+8192
-
-
An Output 1 *
Actual spd (%)
121
-200.0
+200.0
-
-
-
F act spd (rpm)
924
-32768
+32767
-
-
*
Act spd filter [s]
923
0.001
1.000
0.100
0.100
-
Enc 1 speed (rpm)
427
-8192
+8192
-
-
-
Enc 2 speed (rpm)
420
-8192
+8192
-
-
-
Mains voltage [V]
466
0
999
-
-
*
Mains frequency [Hz]
588
0.0
70.0
-
-
-
Output power [Kw]
1052
0.01
9999.99
-
-
-
Output voltage [V]
233
0
999
-
-
*
Motor current [%]
199
-250
250
-
-
*
F T curr (%)
928
-500
+500
-
-
*
T curr filter [s]
926
0.001
0.250
0.100
0.100
-
T current ref [%]
41
-200
+200
-
-
*
Flux reference [%]
500
0.0
100.0
-
-
*
Flux current [%]
234
0.0
100.0
-
-
*
Flux current (A)
351
0.1
99.9
S
S
-
Digital I/Q
-
-
-
Dig input term 1
565
0
1
-
-
-
Dig input term 2
566
0
1
-
-
-
Dig input term 3
567
0
1
-
-
-
Dig input term 4
568
0
1
-
-
-
Dig input term 5
569
0
1
-
-
-
Dig input term 6
570
0
1
-
-
-
Dig input term 7
571
0
1
-
-
-
Dig input term 8
572
0
1
-
-
-
Dig input term 9
573
0
1
-
-
-
Dig input term 10
574
0
1
-
-
-
Dig input term 11
575
0
1
-
-
-
Dig input term 12
576
0
1
-
-
-
Dig input term 15
579
0
1
-
-
-
Dig input term 16
580
0
1
-
-
-
Dig output term
581
0
65535
-
-
-
Virtual dig inp
582
0
65535
-
-
-
Virtual dig out
583
0
65535
-
-
-