4.8

Other Module

— 4-293 —

(2) Acquiring the Replacement Battery

Acquire an ER6VC3N replacement battery. This battery is not commercially
available; it must be ordered from Yaskawa. The battery has special specifica-
tions and is equipped with a connector. It is manufactured by TOSHIBA.

Caution

Do not charge the lithium battery into the Module.

The lithium battery may erupt if charged.

b) Battery Replacement Procedure

Use the following procedure to replace the battery.

(1) Turn OFF the external power supply (24 VDC) to the BAT Module. Once the pow-

er supply to the BAT Module has been turned OFF, it does not matter whether or
not power is supplied to the system (to the SERVOPACKs).

(2) Remove the mounting screws from the front panel. There are two screws, one at

the top and one at the bottom.

(3) Pull the front panel out from the case with the cables still connected to 1CN and

2CN.

Front panel

mounting screw

Front panel mounting screw

Cables

Board

Case

Front panel