Yaskawa MEMOCON GL120 User Manual
Page 145

4.3 CPU Modules
— 4-89 —
2. MEMOBUS Port
1) Through the MEMOBUS ports, the CPU10 Module communicates using RS-232C com-
munications with other communications devices connected to the MEMOBUS network.
2) The following tables list some of the communications devices that can be connected to
MEMOBUS ports. These devices must have an RS-232C interface. For some devices,
the MEMOBUS port settings must be changed. These settings are changed on the DIP
switch on the front of the Module. Refer to the next section, 4. DIP Switch, for details on
setting the DIP switch.
Table 4.31 Devices Connectable to MEMOBUS Port 1
Type
Device
Remarks
MEMOBUS
master devices
P120 Programming Panels
D
The MEMOBUS protocol is used for
communications.
master devices
Personal computers with
MEMOSOFT
communications.
D
A communications program is not required.
ACGC4000/400-series FA
Monitors
D
If the personal computer does not have
MEMOSOFT installed, a communications
TB120 Teaching Pendants
,
program based on the MEMOBUS protocol
will have to be created.
Table 4.32 Devices Connectable to MEMOBUS Port 2
Type
Device
Remarks
MEMOBUS
master devices
P120 Programming Panels
D
Connect MEMOBUS port 2 as a slave port.
Th MEMOBUS
l i
d f
Personal computers with
MEMOSOFT
D
The MEMOBUS protocol is used for
communications.
D
A communications program is not required
ACGC4000/400-series FA
Monitors
D
A communications program is not required.
D
If the personal computer does not have
MEMOSOFT installed, a communications
TB120 Teaching Pendants
MEMOSOFT installed, a communications
program based on the MEMOBUS protocol
will have to be created.
ASCII devices
Bar code readers
D
Connect MEMOBUS port 2 as the master
port.
D
Set MEMOBUS port 2 to Transparent Mode
Printers
D
Set MEMOBUS port 2 to Transparent Mode.
D
Create a communications program in the
CPU10 using the COMM instruction.
Refer to Table 4.33 Specifications of CPU10 for MEMOBUS port communications specifica-
tions.
4