1. Appearance
Terminal block mounting screw
(use M3 Phillips screwdriver)
Color code (yellow)
Removable
terminal block
for field
connections
Hinged
terminal cover
Signal label
inserts
LED area
Module description
(120EHC21110)
Field wiring terminal (use M3 Phillips screwdriver)
Module mounting screw
(Use M4 Phillips screwdriver.)
LED
Color
Indication when ON
RDY
Green
Module is operating normally.
ACT
Green
Module is being serviced by CPU Module.
PHA
Green
Module is detecting the A-phase Encoder pulse.
PHB
Green
Module is detecting the B-phase Encoder pulse.
ENB
Green
Module is ready to count pulse.
ERR
Red
A setting error in Module has occurred.
N0
Green
Module is outputting notch output 0.
N1
Green
Module is outputting notch output 1.
N2
Green
Module is outputting notch output 2.
N3
Green
Module is outputting notch output 3.
Figure 4.69 Appearance of High-speed Counter Module