beautypg.com

Yaskawa MEMOCON GL120 User Manual

Page 316

background image

System Components: Functions and Specifications

4.7.3 One-axis Motion Module cont.

— 4-260 —

Items

Specifications

Absolute Encoder

Backup Circuit

D

Absolute encoder backup circuit will backup revolution data during power
interruptions while absolute encoders are being used.

D

The following are used for backup power supply:

1) Battery Module (Model No.: JRMSP-120XCP96000):

One Battery Module enables the backup of revolution data of up to 8
absolute encoders. When Battery Module is connected to 8 absolute
encoders, it can backup data for 1 year max. However, if encoder is
rotated during this period, the backup period will be less than 1 year.

2) Large-capacity capacitor in absolute encoder

After full recharge, can backup up to 3 days.

D

Battery Module has a built-in battery voltage low-level detection circuit.
The alarm output caused by a low voltage level can be read using a
Digital Input Module.

External Supply

Power

The following external supply power is needed for external I/O signal power:
24 VDC, 1 A

2) Performance Specifications

The following table shows the performance specifications of a One-axis Motion Module.

Table 4.108 Performance Specifications of One-axis Motion Module

Items

Specifications

Number of

Controlled Axes

1 axis

Coordinate Setting

Unit

Linear axis: 0.001 mm min.

Rotary axis: 0.001 degree min.

Maximum

Command Value

± 99,999,999

Maximum

Command Speed

240 m/min

Automatic

Acceleration and

Deceleration

1-step linear acceleration/deceleration,

Asymmetric linear acceleration/deceleration,

S-curve acceleration/deceleration

Override

0% to 100% in 1% increments

Enables variable-speed operation.

Positioning

Function

1) 1-step speed operation

2) Multi-stage speed operation (1 to 16 stages)

3) Through-point output

4) External positioning

Manual Jogging

Possible

Manual Stepping

Possible

Home Position

Return

4 types of home position returns are possible with the combination of

deceleration LS, C-phase pulse, and zero signal.

Stored Stroke

Limits

Upper and lower limits: Enabled or disabled with parameters.

4

This manual is related to the following products: