beautypg.com

Yaskawa MEMOCON GL120 User Manual

Page 304

background image

System Components: Functions and Specifications

4.7.2 Four-axis Motion Module cont.

— 4-248 —

Items

Specifications

Servo Interface Signals

The following signals can be input/output from/to up to four servo amps via the servo

connectors (SV1 to SV4) on the front panel of the Module.

1) Input signals

a) Feedback Input

5-V differential line receiver. AB-phase. Maximum frequency: 1 Mpps (1X). Line
breakage detection.

b) Servo Alarm Input

24 VDC, 5 mA, photocoupler isolation.

2) Output signals

a) Speed Reference Outputs

Analog speed reference outputs. 0 to ±10 VDC.

b) Battery Output

Connect to the battery input of absolute SERVOPACK.

c) SEN Signal Output

Connect to the SEN input of absolute SERVOPACK. 5 VDC, 5 mA.

d) Servo ON Output

24 VDC, 15 mA, photocoupler isolation, open-collector output (sinking output).

e) Servo Reset Output: Same as above

f) PCON Signal Output: Same as above*

* New step-2 command

External I/O Signals

The following signals can be input/output from/to external devices via the I/O signal

collector on the front panel of the Module.

1) Input Signals

a) Number of Signals: 17

b) Signal Names:

Positive overtravel (axes 1 to 4)
Negative overtravel (axes 1 to 4)
Zero signal (axes 1 to 4)
Deceleration signal (axes 1 to 4)
Skip input

c) Input Circuit Specifications

24 VDC, 5 mA, photocoupler isolation, sinking/sourcing inputs.

2) Output Signals

a) Number of Signals: 4

b) Signal Names

Brake outputs (axes 1 to 4)

c) Output Signal Specifications

24 VDC, 50 mA, photocoupler isolation, open-collector outputs (sinking outputs).

4

This manual is related to the following products: