w w w . d i g i e m b e d d e d . c o m
8 2 3
T i m i n g
Notes:
1
CLCDCLK is selected from 5 possible sources:
— lcdclk/2 (lcdclk is an external oscillator)
— AHB clock
— AHB clock/2
— AHB clock/4
— AHB clock/8
See the LCD Controller chapter for acceptable clock frequencies for the different display configurations.
2
The polarity of
CLLP, CLFP, CLCP,
and
CLAC
can be inverted using control fields in the LCDTiming1 register.
3
The CPL field in the LCDTiming2 register must also be programmed to T5-1.
4
The PPL field in the LCDTiming0 register must also be programmed correctly.
L18
CLCP to data/control
(see notes 7 and 8)
-1.0 (min)
+1.5 (max)
ns
L19
CLCP high (see notes 8, 9)
50%±0.5ns
ns
L20
CLCP low (see notes 8, 9)
50%±0.5ns
ns
L21
TFT VSYNC active to HSYNC
active (see note 8)
-0.1ns (min)
+0.1ns (max)
ns
L22
TFT VSYNC active to HSYNC
inactive
LCDTiming0
HSW
CLCP periods
L23
STN VSYNC active to HSYNC
inactive
LCDTiming0
STN color: 14+HSW+HFP
STN Mono8:
6+HSW+HFP
STN Mono4:
10+HSW+HFP
CLCP periods
L24
STN HSYNC inactive to
VSYNC inactive
LCDTiming0
HBP+1
CLCP periods
L25
STN VSYNC inactive to
HSYNC active
LCDTiming0
STN color: HFP+13
STN Mono8: HFP+15
STN Mono4: HFP+9
CLCP periods
L26
CLCP period
12.5ns (min)
ns
Parm
Description
Register
Value
Units
Table 474: LCD timing parameters