Lcd timing – Digi NS9750 User Manual
Page 846
![background image](/manuals/75506/846/background.png)
L C D t i m i n g
8 2 2
N S 9 7 5 0 H a r d w a r e R e f e r e n c e
LCD timing
Note:
All AC characteristics are measured with 10pF, unless otherwise noted.
Table 474 describes the values shown in the LCD timing diagrams (Figure 129 through
Figure 135).
Parm
Description
Register
Value
Units
L1
Horizontal front porch blanking
LCDTiming0
HFP+1
CLCP periods
L2
Horizontal sync width
LCDTiming0
HSW+1
CLCP periods
L3
Horizontal period
N/A
L1+L2+L15+L4
CLCP periods
L4
Horizontal backporch
LCDTiming0
HBP+1
CLCP periods
L5
TFT active line
LCDTiming0
16*(PPL+1)
(see note 3)
CLCP periods
L6
LCD panel clock frequency
LCDTiming1
For BCD=0:
CLCDCLK/(PCD+2)
For BCD=1:
CLCDCLK (see note 1)
MHz
L7
TFT vertical sync width
LCDTiming1
VSW+1
H lines
L8
TFT vertical lines/frame
N/A
L7+L9+L10+L11
H lines
L9
TFT vertical back porch
LCDTiming1
VBP
H lines
L10
TFT vertical front porch
LCDTiming1
VFP
H lines
L11
Active lines/frame
LCDTiming1
LPP+1
H lines
L12
STN HSYNC inactive to
VSYNC active
LCDTiming0
HBP+1
CLCP periods
L13
STN vertical sync width
N/A
1
H lines
L14
STN vertical lines/frame
N/A
L11+L16
H lines
L15
STN active line
LCDTiming2
CPL+1 (see note 4)
CLCP periods
L16
STN vertical blanking
LCDTiming1
VSW+VFP+VBP+1
H lines
L17
STN CLCP inactive to HSYNC
active
LCDTiming0
HFP+1.5
CLCP periods
Table 474: LCD timing parameters