S e r i a l C o n t r o l M o d u l e : U A R T
D05:04
R/W
FLOW3
10
Flow control enable
00
Disabled
01
Disabled
10
Change field FLOW_STATE to XON upon
match
11
Change field FLOW_STATE to XOFF upon
match
Allows you to define the flow control characteristics
using fields RDMB3 (see "RDMB3" on page 634)
and RMMB3 (see "RMMB3" on page 635).
D03:02
R/W
FLOW2
10
Flow control enable
00
Disabled
01
Disabled
10
Change field FLOW_STATE to XON upon
match
11
Change field FLOW_STATE to XOFF upon
match
Allows you to define the flow control characteristics
using fields RDMB2 (see "RDMB2" on page 634)
and RMMB2 (see "RMMB2" on page 635).
D01:00
R/W
FLOW1
10
Flow control enable
00
Disabled
01
Disabled
10
Change field FLOW_STATE to XON upon
match
11
Change field FLOW_STATE to XOFF upon
match
Allows you to define the flow control characteristics
using fields RDMB1 (see "RDMB1" on page 634)
and RMMB1 (see "RMMB1" on page 635).
Bits
Access
Mnemonic
Reset
Description
Table 378: Serial Channel B/A/C/D Flow Control register