8. To save the changes, press the
Enter (Options) key. The following choices appear on
the generator’s display:
•
To save the changes, choose the
Yes item by pressing the adjacent soft key.
•
To exit without saving the changes, choose the
No item.
•
To return to the previous screen without saving the changes, choose the
Back item.
Using the ImageShift utility through the command line interface
The procedures for configuring and running the ImageShift utility from the command line
interface are given below. To run the ImageShift utility from the command line interface,
you must utilize an imageshift file. An imageshift file specifies both the image and
parameters necessary to run the ImageShift utility.
To create an imageshift file:
1. Establish a session with the generator using either HyperTerminal over a serial
connection or Telnet over an Ethernet LAN. See “
Configuring the generator’s serial
” on page 32 or “
Establishing a Telnet session with the generator
2. Set the path to the imageshift files using the ISHP command. For example:
tffs0/library/imageshifts
3. Create a new imageshift file using the ISHN command. For example:
Newshift
4. Define the imageshift file settings as shown in the example below:
//begins an imageshift editing session
/cache0/images/SMPTEBar
//selects the SMPTEBar image
0,0 150,20
//sets the imageshift path x,y coordinates
1
//sets the trace type to Repeat (1)
4
//sets the horizontal shift increment to 4
2
//sets the vertical shift increment to 2
5
//sets the time shift value to 5
//ends the imageshift editing session
5. Save the settings to the same imageshift file using the ISHS command, For example:
//saves the settings to the Newshift file
Apply Settings?
Back